Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Hazardous Areas - Electrical equipment in hazardous areas - pressurisation
Hazardous Areas - Electrical equipment in hazardous areas - pressurisation
Skill set
National Code
UEESS00115
UEESS00115
State Code
AC554
AC554
TGA Status
Deleted
Deleted
DTWD Status
Deleted
Deleted
National Endorsed, State Implementation and Classification
AQF Level
—
Field of Education
—
Skillset Type
National
Original TGA Release Date
14/08/2013
Current Release Date
14/08/2013
Current Release Number
1.00
Approved Date
22/12/2017
Nominal Hours
216
Duration
1 Semester
Releases
| Release Version | Release Date | TGA Status | DTWD Status |
|---|---|---|---|
| 1.00 | 14/08/2013 | Current | Approved |
Description
This Skill Set covers the explosion-protection aspects for pressurised atmospheres of installing, maintaining, testing inspecting and attending to breakdowns of explosion-protected and associated equipment. It requires the ability to follow specifications, standards and work programs, work safely and complete the necessary documentation.
This Skill Set is directly equivalent to Unit 2.3 Attend to breakdowns in hazardous areas, Unit 2.5 Install Explosion-Protected equipment and wiring systems, Unit 2.7 Maintain equipment in hazardous areas, Unit 2.10 Conduct testing of hazardous areas installations, Unit 2.12 Conduct detailed inspection of hazardous areas installations and Unit 2.2 Report on the integrity of explosion-protected equipment in hazardous areas in the Australian/New Zealand Standard AS/NZS 4761.1 Competencies for working with electrical equipment for hazardous areas (EEHA) Part 1: Competency Standards. Equivalence includes endorsement in the explosion-protection techniques listed in the Range statement of this Skill Set.
This Skill Set is directly equivalent to Unit 2.3 Attend to breakdowns in hazardous areas, Unit 2.5 Install Explosion-Protected equipment and wiring systems, Unit 2.7 Maintain equipment in hazardous areas, Unit 2.10 Conduct testing of hazardous areas installations, Unit 2.12 Conduct detailed inspection of hazardous areas installations and Unit 2.2 Report on the integrity of explosion-protected equipment in hazardous areas in the Australian/New Zealand Standard AS/NZS 4761.1 Competencies for working with electrical equipment for hazardous areas (EEHA) Part 1: Competency Standards. Equivalence includes endorsement in the explosion-protection techniques listed in the Range statement of this Skill Set.
Pathway Information
The units of competency in this skill set will contribute to the completion of relevant Certificate IV, Diploma and Advanced Diploma qualifications from the UEE11 Electrotechnology Training Package. Please consult the packaging rules of the relevant qualification for further advice.
Licensing / Regulatory Information
The skills and knowledge described in this skill set are subject to regulatory requirements including applicable WHS/OHS and Electrical regulations and compliance with applicable Australian Standards.
Where plant and equipment operate at voltages above 50 V a.c. or 120 V d.c. a license to practice in the workplace is required.
Subject to applicable regulations including relevant WHS/OHS regulations, in some jurisdictions, a license to practice may be required to carry at work at extra low voltage.
Other conditions related to communications, electrical work, fire protection, gas work, high voltage work, refrigeration/air conditioning and security may apply in some jurisdictions subject to regulations.
Practice in the workplace and during training is also subject to regulations directly related to occupational health and safety and where applicable contracts of training such as apprenticeships.
Where plant and equipment operate at voltages above 50 V a.c. or 120 V d.c. a license to practice in the workplace is required.
Subject to applicable regulations including relevant WHS/OHS regulations, in some jurisdictions, a license to practice may be required to carry at work at extra low voltage.
Other conditions related to communications, electrical work, fire protection, gas work, high voltage work, refrigeration/air conditioning and security may apply in some jurisdictions subject to regulations.
Practice in the workplace and during training is also subject to regulations directly related to occupational health and safety and where applicable contracts of training such as apprenticeships.
Target Group
Those undertaking this skill set should hold:
Competency required by a given industry or enterprise for plant or machinery operation or installations, maintenance or service functions at least at AQF 3 or equivalent.
or
Competencies in attending to breakdowns in general electrical or instrumentation equipment mechanical plant/equipment service and maintenance at least at AQF level 3 or equivalent.
or
Competencies in installation of general low-voltage or extra-low voltage electrical /electronic equipment and wiring systems at AQF 3 or equivalent.
or
Competencies in conducting testing of general electrical, electronic, instrumentation and/or data communication installations has been achieved at AQF 3 or equivalent.
Competency required by a given industry or enterprise for plant or machinery operation or installations, maintenance or service functions at least at AQF 3 or equivalent.
or
Competencies in attending to breakdowns in general electrical or instrumentation equipment mechanical plant/equipment service and maintenance at least at AQF level 3 or equivalent.
or
Competencies in installation of general low-voltage or extra-low voltage electrical /electronic equipment and wiring systems at AQF 3 or equivalent.
or
Competencies in conducting testing of general electrical, electronic, instrumentation and/or data communication installations has been achieved at AQF 3 or equivalent.
Suggested words for statement of attainment
This Skill Set from the UEE11 Electrotechnology Training Package meets the industry requirements for Hazardous Areas - Electrical equipment in hazardous areas - pressurisation
General notes
Schedule
| State Code | National Code | Title | Hours | Type |
|---|---|---|---|---|
| D3588 | UEENEEM022A | Attend to breakdowns in hazardous areas - pressurisation | 18 | Unit of competency |
| D3612 | UEENEEM046A | Conduct detailed inspection of hazardous areas installations - pressurisation | 36 | Unit of competency |
| D3607 | UEENEEM041A | Conduct testing of hazardous area installations - pressurisation | 36 | Unit of competency |
| D3592 | UEENEEM026A | Install explosion-protected equipment and wiring systems - pressurisation | 54 | Unit of competency |
| D3596 | UEENEEM030A | Maintain equipment in hazardous areas - pressurisation | 54 | Unit of competency |
| D3645 | UEENEEM080A | Report on the integrity of explosion-protected equipment in a hazardous area | 18 | Unit of competency |